IDC NLST: Lung Cancer, Non-Cancer CT, whole-slide microscopy (26,410 patients): sample notebook
A worked notebook for IDC NLST: Lung Cancer, Non-Cancer CT, whole-slide microscopy (26,410 patients), with 7 code cells and the output each one printed. On Scigantic it opens in a hosted JupyterLab with the dataset already mounted, so nothing is downloaded first.
- Provider
- NCI Imaging Data Commons; NLST contributors; tables and sample by Scigantic
- License
- Per series (series.parquet license_short_name): CC BY 4.0 591,341, CC BY 3.0 1,259. Cite the source DOI(s) and the IDC.
- Size
- 12 parquet tables plus 61 sample DICOM files (13 MB)
- Stored at
- Amazon S3, s3://scigantic-idc-open/nlst (us-east-1)
- Access
- Free and public. No account with the data provider is needed.
- DOI
- 10.7937/tcia.hmq8-j677
The notebook
NLST on the Imaging Data Commons: 26,410 patients, 592,600 series, 25,749.68 GB
Lung Cancer, Non-Cancer imaging of the chest from the NCI Imaging Data Commons (IDC). Series by modality: SR 257,391, CT 203,111, SEG 130,839, SM 1,259.
This mount is the collection's index plus a real sample, not the collection: series.parquet (one row per DICOM series, with the public S3 location of each), studies.parquet, patients.parquet, the IDC clinical tables, and sample/ folders holding one CT series (CC BY 4.0); one SEG series (CC BY 4.0); one SM slide (thumbnail + two smallest pyramid levels) (CC BY 3.0). Anything else is one anonymous S3 read away. README.md and BUILD_REPORT.json at the mount root say exactly how this was built (idc-index, IDC v25).
The code below reads all of it with the scigantic-nci package (pip install "scigantic-nci[dicom]", already installed in this image): from scigantic_nci import idc, then calls such as idc.series("nlst"), idc.read_sample and idc.pull_series. Run anywhere else, the same calls read s3://scigantic-idc-open/nlst/ anonymously.
import os, json
import numpy as np
import pandas as pd
import matplotlib.pyplot as plt
import pydicom
from scigantic_nci import idc, NciError
plt.rcParams['figure.dpi'] = 72 # keeps the saved figures small enough for the notebook preview
try:
from matplotlib_inline.backend_inline import set_matplotlib_formats
set_matplotlib_formats('jpeg') # slide renders are photographic; JPEG is a fifth the size of PNG here
except ImportError:
pass
C = 'nlst'
# scigantic_nci reads the mounted archive when its BUILD_REPORT.json names this collection, else s3://scigantic-idc-open/<collection>/ anonymously.
M = os.environ.get('SCIGANTIC_MOUNT_PATH', '/mnt/archive')
on_mount = os.path.exists(f'{M}/BUILD_REPORT.json') and json.load(open(f'{M}/BUILD_REPORT.json')).get('collection_id') == C
print('reading', C, 'from', M if on_mount else f's3://scigantic-idc-open/{C}/')
report = idc.report(C)
series = idc.series(C) # one row per DICOM series, with its public S3 location
patients = idc.patients(C)
studies = idc.studies(C)
print(report['collection_name'], '| IDC', report['idc_data_version'], '| built', report['built_at'][:10])
print(f"{len(patients):,} patients, {len(studies):,} studies, {len(series):,} series, {series.series_size_MB.sum()/1024:,.1f} GB in the IDC buckets\n")
by_mod = series.groupby('Modality').agg(series=('SeriesInstanceUID', 'count'), patients=('PatientID', 'nunique'), GB=('series_size_MB', lambda s: round(s.sum() / 1024, 2))).sort_values('series', ascending=False)
print(by_mod.to_string())
fig, ax = plt.subplots(figsize=(7, 3))
by_mod['patients'].plot.bar(ax=ax, color='#4a6fa5'); ax.set_ylabel('patients'); ax.set_title(f"{report['collection_name']}: patients per modality"); plt.tight_layout()
Output:
reading nlst from /mnt/archive
NLST | IDC v25 | built 2026-11-17
26,410 patients, 73,574 studies, 592,600 series, 25,749.7 GB in the IDC buckets
series patients GB
Modality
SR 257391 26205 138.35
CT 203111 26254 10878.51
SEG 130839 26203 13884.90
SM 1259 452 847.93
1. Studies and patients
A study is one imaging visit (all series acquired together); a patient may have several. studies.parquet collapses the series table to one row per study with the modalities present, patients.parquet to one row per patient.
print('Studies per patient:'); print(patients.n_studies.describe()[['min', '50%', 'max']].to_string())
print('\nModality combinations per study (top 8):'); print(studies.modalities.value_counts().head(8).to_string())
sex = patients.PatientSex.replace('', np.nan).dropna()
if len(sex): print('\nPatientSex:', sex.value_counts().to_dict())
ages = pd.to_numeric(series.PatientAge.dropna().astype(str).str.extract(r'(\d+)')[0], errors='coerce')
if ages.notna().sum() > 10: print(f'PatientAge at imaging: median {ages.median():.0f} y (IQR {ages.quantile(.25):.0f}-{ages.quantile(.75):.0f}) on {ages.notna().sum():,} series')
if 'BodyPartExamined' in series: print('\nBodyPartExamined:', series.BodyPartExamined.dropna().value_counts().head(6).to_dict())
print('\nLicenses (per series):', series.license_short_name.value_counts().to_dict())
Output:
Studies per patient:
min 1.0
50% 3.0
max 5.0
Modality combinations per study (top 8):
modalities
CT, SEG, SR 71677
CT 1419
SM 461
CT, SEG 9
CT, SR 8
PatientSex: {'M': 274, 'F': 178}
PatientAge at imaging: median 64 y (IQR 60-68) on 1,259 series
...
2. Open the sample CT series
sample/CT_1.2.840.113654.2.55.32083182320803884952517988249810767148/ is the complete series of patient 119802 (57 instances, 7.6 MB, CC BY 4.0), copied byte-for-byte from s3://idc-open-data/53221465-de4f-41e8-bf50-558eea53e27c/*. One .dcm per slice; idc.read_sample sorts them on ImagePositionPatient[2] (InstanceNumber as a fallback) and stacks them, applying RescaleSlope/RescaleIntercept so values are Hounsfield units. The pydicom datasets are in vol.datasets.
try:
vol = idc.read_sample(C, 'CT') # Volume: instances sorted by ImagePositionPatient z then InstanceNumber, CT in Hounsfield units
except NciError as e: # compressed transfer syntax with no decoder plugin in this image
print(e, 'Skipping the render.')
vol = None
if vol is not None:
n = len(vol.datasets)
if vol.array is not None and n >= 3:
lo, hi = -160, 240 # soft-tissue window in Hounsfield units
picks = [(vol.array[i], f'slice {i + 1}/{n}') for i in (n // 4, n // 2, 3 * n // 4)]
else: # 2D modalities or a series that mixes image sizes (scouts, crops): show instances one by one
imgs = vol.images if vol.ragged else list(vol.array)
picks = [(img, f'{d.get("SeriesDescription", "")} {img.shape[1]}x{img.shape[0]}') for img, d in zip(imgs[:3], vol.datasets[:3])]
flat = np.concatenate([p[0].ravel() for p in picks]); lo, hi = np.percentile(flat, 1), np.percentile(flat, 99)
shapes = sorted({im.shape for im in vol.images}) if vol.ragged else [vol.array.shape[1:]]
d0 = vol.datasets[0]
print(f'{vol.modality} {n} instances, image shapes {shapes} | spacing {d0.get("PixelSpacing") or d0.get("ImagerPixelSpacing")} mm, slice thickness {d0.get("SliceThickness")} mm | {d0.get("Manufacturer")} {d0.get("ManufacturerModelName")} | {d0.get("SeriesDescription")}')
fig, axes = plt.subplots(1, len(picks), figsize=(3.6 * len(picks), 3.8))
for ax, (img, label) in zip(np.atleast_1d(axes), picks):
ax.imshow(img if img.ndim == 2 else np.clip((img - lo) / max(hi - lo, 1e-6), 0, 1), cmap='gray', vmin=lo, vmax=hi); ax.set_title(label, fontsize=9); ax.axis('off') # RGB (ultrasound) is scaled to 0-1
plt.suptitle(f"NLST: sample CT series, patient 119802"); plt.tight_layout()
Output:
CT 57 instances, image shapes [(256, 256)] | spacing [1.375, 1.375] mm, slice thickness 5 mm | SIEMENS Volume Zoom | 1,OPA,SE,VZOOM,B30f,352,5,120,70,40,na
3. The sample segmentation
sample/SEG_1.2.276.0.7230010.3.1.3.481037312.288665.1761249018.481405/ is a DICOM SEG series of patient 126576 (0.1 MB, CC BY 4.0): a stack of binary frames, one per segment and source slice, with SegmentSequence naming each segment and ReferencedSeriesSequence pointing at the image series it was drawn on. A few collections label ordinary image instances (one label map per slice) as SEG; the cell handles both. idc.sample_files lists the files; on the mount they are read in place, and elsewhere the same series is pulled from IDC with idc.pull_series. The source image series can be pulled from IDC the same way as any other row of series.parquet.
# scigantic_nci has no SEG reader, and read_sample decodes one frame per instance, which pydicom cannot do for some 1-bit SEG objects,
# so the SEG files are read whole with pydicom: in place on the mount (sample_files gives paths relative to the archive root), else pulled from IDC.
seg_sample = idc.samples(C).query("modality == 'SEG'").iloc[0]
if on_mount:
seg_files = [os.path.join(M, f) for f in idc.sample_files(C, 'SEG')]
else:
seg_files = idc.pull_series(series[series.SeriesInstanceUID == seg_sample.SeriesInstanceUID].iloc[0], '/tmp/idc_pull/' + seg_sample.SeriesInstanceUID)
seg_ds = [pydicom.dcmread(f) for f in seg_files]
seg = seg_ds[0]
if 'SegmentSequence' in seg: # a DICOM Segmentation object
print(seg.Modality, seg.get('SeriesDescription'), '|', int(seg.get('NumberOfFrames', 1)), 'frames of', seg.Rows, 'x', seg.Columns, '|', seg.get('ContentCreatorName'))
print('segments:', [(int(x.SegmentNumber), str(x.SegmentLabel), str(x.get('SegmentAlgorithmType'))) for x in seg.SegmentSequence][:8])
mask = seg.pixel_array
else: # labelled SEG but stored as ordinary images: one label map per slice
seg_ds.sort(key=lambda d: (float(d.ImagePositionPatient[2]) if 'ImagePositionPatient' in d else 0.0, int(d.get('InstanceNumber', 0))))
print(seg.Modality, seg.get('SeriesDescription'), '|', len(seg_ds), seg.SOPClassUID.name, 'instances of', seg.Rows, 'x', seg.Columns, '(label maps, not a Segmentation object)')
mask = np.stack([d.pixel_array for d in seg_ds])
values, counts = np.unique(mask, return_counts=True)
mask = mask != values[counts.argmax()] # label maps carry a nonzero background value; everything else is labelled
ref = seg.ReferencedSeriesSequence[0].SeriesInstanceUID if 'ReferencedSeriesSequence' in seg else None
src = series[series.SeriesInstanceUID == ref]
if len(src):
r = src.iloc[0]
print(f'drawn on the {r.Modality} series of patient {r.PatientID}: {int(r.instanceCount)} instances, {r.series_size_MB:.1f} MB, {r.license_short_name}, {r.series_aws_url}')
mask = (mask[None] if mask.ndim == 2 else mask) > 0
i = int(mask.reshape(mask.shape[0], -1).sum(1).argmax()) # the frame with the most labelled pixels
print(f'{int(mask.sum()):,} labelled pixels over {mask.shape[0]} frames; densest frame {i + 1}')
fig, ax = plt.subplots(figsize=(3.8, 3.8)); ax.imshow(mask[i], cmap='gray'); ax.axis('off'); ax.set_title(f"NLST: sample SEG, frame {i + 1}", fontsize=9); plt.tight_layout()
Output:
SEG NLSTSeg Segmentation of Series: 3 | 2 frames of 512 x 512 | IDC segments: [(1, 'Lesion 1 - Tumor - Upper lobe of right lung', 'MANUAL')] 650 labelled pixels over 2 frames; densest frame 2
4. Open the sample whole-slide image
Slide microscopy in IDC is DICOM WSI: every resolution level of the pyramid is its own instance, tiled into frames. sample/SM_1.3.6.1.4.1.5962.99.1.489247787.386618194.1641166787627.2.0/ holds the thumbnail and the two smallest levels of one slide of patient 133530 (the full slide is 33 MB in 5 instances). idc.read_sample lists the levels, lowest resolution first, and level(i) assembles one from its tiles (idc.assemble_level(path) does the same for any WSI instance on disk); idc.slides is the slide table with the stain flattened to text. wsidicom (installed here) reads arbitrary regions of a full slide.
slide = idc.read_sample(C, 'SM') # SlideLevels: one entry per pyramid instance, lowest resolution first
for lv in slide.levels: print(f'{lv.width:6d} px wide {lv.image_type}')
top = slide.levels[-1]
img = slide.level(top.index) # tiles assembled row-major into one array
print(f'assembled {img.shape[1]} x {img.shape[0]} px from {top.n_frames} tiles of {top.rows} x {top.cols}' + (f', {top.um_per_px:.2f} um/px at this level' if top.um_per_px else ''))
stains = idc.slides(C)['stain'].dropna() # sm_series joined to series, list-valued stain codes flattened to text
print('stains in the collection:', stains.value_counts().head(4).to_dict())
step = max(1, int(np.ceil(max(img.shape[:2]) / 700))) # show at most ~700 px on the long side
shown = img[::step, ::step]
fig, ax = plt.subplots(figsize=(6, 6 * shown.shape[0] / shown.shape[1])); ax.imshow(shown, cmap=None if shown.ndim == 3 else 'gray'); ax.axis('off'); ax.set_title(f"NLST: sample slide, patient 133530"); plt.tight_layout()
Output:
659 px wide THUMBNAIL
1280 px wide OVERVIEW
1495 px wide VOLUME
assembled 1495 x 1741 px from 42 tiles of 256 x 256, 4.02 um/px at this level
stains in the collection: {'hematoxylin stain, water soluble eosin stain': 1259}
5. Clinical tables
IDC ships 5 clinical table(s) for this collection (nlst_canc, nlst_ctab, nlst_ctabc, nlst_prsn, nlst_screen; idc.clinical_tables lists them), keyed by dicom_patient_id = PatientID. clinical/dictionary.parquet (idc.clinical_dictionary) carries the human-readable label and the coded values for every column; coded columns store the code.
clin = idc.clinical(C, 'nlst_canc')
dictionary = idc.clinical_dictionary(C)
print(clin.shape, 'rows x cols in', 'nlst_canc')
print(dictionary[dictionary.short_table_name == 'nlst_canc'][['column', 'column_label']].head(15).to_string(index=False))
joined = patients.merge(clin, left_on='PatientID', right_on='dicom_patient_id', how='left')
print(f'\n{joined.dicom_patient_id.notna().sum()} of {len(patients)} imaged patients have a clinical row')
Output:
(2150, 36) rows x cols in nlst_canc
column column_label
dicom_patient_id idc_provenance_dicom_patient_id
source_batch idc_provenance_source_batch
pid pid
lc_topog ICD-O-3 Topography: ICD-O-3 topography of lung cancer.
...
6. Pull any series from IDC on demand
The collection is 25,749.68 GB in s3://idc-open-data (and idc-open-data-cr for CC BY-NC series); it is not on this mount. Every row of series.parquet has aws_bucket and crdc_series_uuid; the objects under that prefix are the series' instances. idc.pull_series(row, dest) takes such a row and downloads the instances anonymously, so this needs no credentials. Check series_size_MB before pulling: a pod has a few GB of local disk.
cand = idc.series(C, modality='CT', max_size_mb=20).sort_values('series_size_MB') # filters pushed down to parquet
row = cand.iloc[len(cand) // 2] if len(cand) else series.sort_values('series_size_MB').iloc[0]
print(row.PatientID, row.Modality, int(row.instanceCount), 'instances,', round(idc.series_size(row), 1), 'MB ->', row.series_aws_url)
print('IDC viewer:', idc.viewer_url(row))
files = idc.pull_series(row, '/tmp/idc_pull') # anonymous read of s3://<aws_bucket>/<crdc_series_uuid>/, returns the local paths
d = pydicom.dcmread(files[0], stop_before_pixels=True)
print(len(files), 'files downloaded;', d.Modality, d.get('SeriesDescription'), d.get('Rows'), 'x', d.get('Columns'))
Output:
123826 CT 1 instances, 1.3 MB -> s3://idc-open-data/1ef1c0b4-9e19-4ea7-b018-46fd2b514399/* IDC viewer: https://viewer.imaging.datacommons.cancer.gov/viewer/1.2.840.113654.2.55.320622905901544197057745450856043040957?seriesInstanceUID=1.2.840.113654.2.55.281240625954870098115610454398777254065 1 files downloaded; CT 1,OPL,GE,LSQX,EXPERIMENTAL7,0,na,80,0,0,na 733 x 888
Try this in the AI assistant
The chat panel is prefilled with the first of these.
- *Show me the sample CT series slice by slice and describe what anatomy is in it.*
- *Assemble the largest sample slide level, estimate how much of it is tissue versus background, and describe the stain.*
- *Which clinical variables in nlst_canc are most complete, and how do they relate to the imaging studies per patient?*
- *Pick the smallest CT or MR series for three different patients, download them, and compare voxel spacing and field of view.*
Licenses are per series (license_short_name in series.parquet). Cite the collection DOI(s) in README.md and the IDC papers (Fedorov et al. 2021, 2023) when you publish.
Run it
Open this notebook to run it, see the dataset page for the full description, or browse the full catalog.